1 Fluids which do not swell, soften or adversely affect any of the filter components. 2 Not recommended where the temperature is cycled by more than 28 °C (50 °F). Maximum temperatures are for continuous service. Figure 1: Ultipleat filter element construction, showing unique laid-over pleats and uniform flow distribution Typical Flow Rates 3 3 Typical initial clean …
The Ultipleat CAS High Flow Filter element is a large diameter, disposable, pleated, filter cartridge for high flow rates in water, with an inside-to-outside flow pattern. The filter is intended for use …
T200 Series Tank Mounted Filters . Ultipleat® SRT . The Ultipleat SRT filter elements are designed with a coreless, cageless element configuration and Pall's Stress-Resistant Technology. They have been replaced by Pall Athalon filter elements that fit directly into Ultipleat SRT filter housings without the need for adaptors. PALLsorb
To install a filter element, remove the element hold down plate by lifting it off the locating pins. Lubricate the O-ring on the open-end of the filter with a compatible fluid, and slide the closed …
Profile® II and Ultipleat® Profile® Filter Elements Retrofit Series - Profile® II and Ultipleat® Profile® Filter Elements Retrofit Series
Ultiplea t® High Flow Series Filter Cartridges Data Sheet PIUHFENd Description The Ultipleat® High Flow filter is a large-diameter, coreless, single open-ended, pleated cartridge with an inside-to-outside flow pattern. The filter's unique crescent-shaped pleat geometry, combined with its large 152.4 mm (6-inch) diameter and
These gas filter elements are successfully used in several applications that demand efficient protection of critical downstream equipment and units. The filter element is built to a very high standard of quality assurance and cleanliness. The depth filter element complies with BS EN ISO 9001:2015 standards. The Profile Coreless gas filter ...
UH319MM Series Ultipleat SRT High Pressure Filters - UH319MM Series Ultipleat SRT High Pressure Filters ... All replacement filter elements, differential pressure indicators and sealkits remain available for this series. ... contact Pall. Table 1: Filter Element Options : Code: ßx(c) ≥1000 based on ISO 16889: CST Rating* AZ: 3: 08/04/01: AP ...
Ultipleat® High Flow Filter Elements with Profile® UP Media: These pleated high flow filters are designed to withstand high flow rates up to 113 m3/hour (500 US gal/min) in a single 1524 mm …
The Ultipleat High Flow filter elements utilize polyethersulfone (PES) media with unique, laid-over pleat geometry. The Ultipleat High Flow element is a large diameter, single open ended, pleated cartridge with an inside to outside flow pattern and a core-free construction.
This value is the pressure drop across the Ultipleat High Flow filter(s) only; it must be added to the pressure drop contribution from the Ultipleat High Flow filter housing. 5) The test procedure used is an adaptation of ISO 4572, modified to determine the micron size above which particles are quantitatively removed.
UT279 Series Ultipleat® SRT In-Tank Filters - UT279 Series Ultipleat® SRT In-Tank Filters All. All; Products; Webpages; Documents; Webinars ... All replacement filter elements, differential pressure indicators and sealkits remain available for this series. ... contact Pall. Table 1: Filter Element Options : Code: ßx(c) ≥1000 based on ISO ...
The Ultipleat® High Flow filter is a large-diameter, coreless, single open-ended, pleated cartridge with an inside-tooutside flow pattern. The filter's unique crescent-shaped pleat geometry, combined with its large 152.4 mm (6-inch) diameter and proprietary range of available Pall filter media, allows you to use significantly fewer filters and smaller housings for high flow-rate …
High flow rate per filter cartridge. Available in a variety of filter lengths and grades. Absolute-rated filter medium for reproducible performance. Features proprietary unique crescent-shaped pleat …
The Ultipleat High Flow Series Filters are available in the following configurations – Ultipleat® High Flow Filters: This filter has a large diameter, coreless, single open-ended, pleated cartridge with an inside to outside flow pattern. It reduces the number of filters and size of housings required with its unique crescent-shaped pleat geometry, combined with its large 152.4 mm (6 …
manufacturing process. As a result, Profile II filters show no media migration. Pall Ultipleat Profile filters are 21⁄ 2 inch diameter pleated polypropylene cartridges. Just like Profile II filters, the absolute rated filter medium within Ultipleat Profile elements is …
Pall Oil Filter Element Replacement can be directly use in Pall oil purifiers, Pall duplex filter housings and Pall pressure filters to help you effectively remove particles and achieve wanted cleanliness level.
The Ultipleat High Flow Series Filters are available in the following configurations – Ultipleat® High Flow Filters: This filter has a large diameter, coreless, single open-ended, pleated cartridge with an inside to outside flow pattern. It reduces …
Ultipleat® High Flow, Filter Grade 4.5μm, Length 60 inches: View Product > HFU640UY045J: Ultipleat® High Flow, Filter Grade 4.5μm, Length 40 inches: View Product > HFU640UY045H13: Ultipleat® High Flow, Filter Grade 4.5μm, Length 40 inches: View Product > HFU620UY045J: Ultipleat® High Flow, Filter Grade 4.5μm, Length 20 inches: View ...
The Ultipleat High Flow filter elements utilize polyethersulfone (PES) media with unique, laid-over pleat geometry. The Ultipleat High Flow element is a large diameter, single open ended, pleated cartridge with an inside to outside flow pattern and a core-free construction.
the open-end of the filter with a compatible fluid, and slide the closed end of the filter into the perforated cage, which is welded to the tubesheet. Seat the elements in place by pressing down on the open-end of the filter until the element is snug in the tubesheet. This provides a seal between the filter and housing via the filter O-ring.
Ultipleat High Flow elements are available in other filter®media with absolute ratings of 2, 4.5, 10, 20, 40 and 100 ®m. Contact Pall for more information. Housing Design A single element, sanitary designed housing is available for …
The Ultipleat High Flow filter elements utilize polyethersulfone (PES) media with unique, laid-over pleat geometry. The Ultipleat High Flow element is a large diameter, single open ended, pleated cartridge with an inside to outside flow pattern and a core-free construction.
Order Pall's pleated Ultipleat High Flow filter elements to remove fine particles and cysts from fluids. Get low-cost filtration and installation with high flow rates.
Ultipleat filter element construction, showing uniform flow distribution Ultipleat High Flow filter elements are designed for high particle removal efficiency of fine particulates from water applications. Description The Ultipleat High Flow filter elements utilize polyethersulfone (PES) media with unique, laid-over pleat geometry.
Pall Profile® II depth filters and Pall Ultipleat® Profile® pleated filters are now available in a user-friendly SI configuration. The SI style element consists of a solid polypropylene endcap with a 302 series stainless steel spring on one end, and a polypropylene endcap holding a replaceable polyethylene gasket on the open end.
Achieve cost-effective and efficient fine particle removal from water at a high flow rate with Pall's Ultipleat® filter elements that come with 1 um filter grade. Explore now.
UR319 Series Ultipleat® SRT Return Line Filters - UR319 Series Ultipleat® SRT Return Line Filters ... All replacement filter elements, differential pressure indicators and sealkits remain available for this series. ... contact Pall. Table 1: Filter Element Options : Code: ßx(c) ≥1000 based on ISO 16889: CST Rating* AZ: 3: 08/04/01: AP: 5: ...
UT319 Series Ultipleat® SRT In-Tank Filters - UT319 Series Ultipleat® SRT In-Tank Filters ... All replacement filter elements, differential pressure indicators and sealkits remain available for this series. ... Other options are available; contact …
Ultipleat High Flow UY Series filter elements comprise materials that meet regulatory and legislative requirements and guidelines for food contact in that: Europe . The "W" Code UY Series Ultipleat High Flow filter elements meet the requirements for food contact as detailed in European Regulation (EC) Number 1935/2004 in that:
Ultipleat® High Flow Filter Elements CAS Series "W" Code Element Part Number HFU 6 CAS010 J U W This is a guide to the part numbering structure only. For specific options, please contact Pall. Table 1 : Nominal Length 40